KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask

3M

£4.50 

  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
  • 3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve

This variant is currently sold out

Please fill in the form below if you'd like to be notified when it becomes available.

3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask

  • Standard Size
  • 9501+ is the code for a Ear-loop Design
  • No Breathing Valve
  • Manufactured by 3M
  • GB2626-2006 KN95 Standard
  • Batch Manufactured Date: 05/03/2020
Please note:

The original packaging of this product contains 50 pieces of respirators. When ordering quantities lower than 50, this product will be packed separately into a clean plastic self-seal bag, and will not arrive in it's original packaging. This does not effect the quality of the respirator. However, if you are uncomfortable with this, please only order multiples of 50, which will arrive in its original packaging, sealed with 3M's authentication sticker. 

For bulk discount, please contact sales@bonroyinternational.com 

3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve

KN95 Standard is equivalent to N95 and FFP2 Standard

3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve

 

IMPORTANT:


Before use, the wearer must read and understand these User Instructions. Keep
these instructions for reference.

Fitting Instructions: Must be followed each time respirator is
worn.

3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
1. Cup the respirator in your hand, with the nosepiece at your fingertips, allowing
the headbands to hang freely below your hand.


2. Position the respirator under your chin with the nosepiece up. Pull the top strap
over your head resting it high at the top back of your head. Pull the bottom
strap over your head and position it around the neck below the ears. Make
certain hair, facial hair, jewellery and clothing are not between your face and the
respirator as they will interfere with fit.


3. Place your fingertips from both hands at the top of the metal nosepiece. Using
two hands, mold the nose area to the shape of your nose by pushing inward
while moving your fingertips down both sides of the nosepiece.
Pinching the nosepiece using one hand may result in improper fit and less
effective respirator performance (Use two hands).


4. Perform a User Seal Check. To check the respirator-to-face seal, place both
hands completely over the respirator and exhale. Be careful not to disturb the
position of the respirator. If air leaks around nose, readjust the nosepiece as
described in step 3. If air leaks around the respirator edges, adjust position of
straps and make certain respirator edges fit snugly against the face. If you
CANNOT achieve a proper seal, DO NOT enter the contaminated area. See
your supervisor.


Removal Instructions:

3M 9501+ KN95/N95/FFP2 Disposable Filtering Facepiece Particulate Respirator Face Mask, Standard Size, Ear-loop, No Valve
1. Without touching the respirator, slowly lift the bottom strap from around
your neck up and over your head. Then lift off the top strap. Store or discard
according to your facility’s infection control policy. Dispose of used product in
accordance with applicable regulations.

 

Description:

The 3M™ Health Care Particulate Respirator is designed to help provide respiratory protection for the wearer. This respirator has
a filter efficiency level of at least 95% against particulate aerosols free of oil†. It is
fluid resistant‡ and meets > 99% bacterial filtration efficiency (BFE)±. It is disposable
and may be worn in surgery. It can fit a wide range of face sizes.

  • This product contains no components made from natural rubber latex.

 

Intended Use:

This product meets CDC guidelines for M.tuberculosis exposure control. As a
respirator, it is intended to help reduce wearer exposure to certain airborne
particles, including those generated by electrocautery, laser surgery, and other
powered medical instruments. As a surgical mask, it is designed to be fluid resistant
to splash and spatter of blood and other infectious materials‡.


Contraindications:


3M recommends that this respirator is not for industrial use. Not for use with
beards or other facial hair or conditions that prevent a good seal between the
face and the sealing edge of the respirator. Does not protect against gases or
vapours (i.e. anaesthetic gases such as isoflurane or vapours from sterilants such as
glutaraldehyde). This respirator was not designed to be used by children.


† Tested against a 0.3 micron particle (mass median aerodynamic diameter) per U.S. 42 CFR 84.
‡ Meets ASTM Fluid Resistant Challenge F1862.
± Meets ASTM Standard Test Method for Bacterial Filtration Effi ciency F2101.

 

Use Instructions:

1. In the U.S., before occupational use of this respirator, a written respiratory
protection program must be implemented meeting all requirements of U.S. OSHA
29 CFR 1910.134 such as medical evaluation, training and fit testing. Select
and use respirator in accordance with all applicable regulations, standards and
professional guidance. Fit testing must be performed while the test subject
is wearing any applicable safety equipment that may be worn during actual
respirator use which could interfere with respirator fit, such as hair bonnets and
eyewear. In Canada, CSA standard Z94.4 requirements must be met. Follow
all applicable local regulations. This respirator is designed for occupational/
professional use by adults who are properly trained in its use and limitations.
The 3M FT-10 (sweet solution) or FT-30 (bitter solution) Qualitative Fit Test
Apparatus or other OSHA accepted fit test protocols are recommended for fit
testing this respirator.

2. Inspect respirator before each use to ensure that it is in good operating
condition. Examine all the respirator parts for signs of damage including the two
headbands, staples, noseclip, nosefoam and facepiece material. Ensure there
are no holes in the breathing zone other than the punctures around staples
and no damage has occurred. Enlarged holes resulting from ripped or torn filter
material around staple punctures are considered damaged. Staple perforations
do not affect NIOSH approval. The respirator should be disposed of immediately
upon observation of damage or missing parts.


3. Leave the contaminated area immediately and contact your supervisor if
dizziness, irritation or other distress occurs.


4. Respirator may be used until damaged, breathing becomes difficult or
contaminated with blood or body fluids. Discard after every use when used for
surgical procedures. Follow national, state, local and facility infection control
guidance and policies.



Storage Conditions and Shelf Life:


Before use, store respirators in the original packaging, away from contaminated
areas, dust, sunlight, extreme temperatures, excessive moisture and damaging
chemicals. When stored in original packaging between temperatures from -4°F
(-20°C) to +86°F (+30°C) and not exceeding 80% RH, the product may be used
until the date specified on packaging located next to the “Use by Date” symbol.

Similar Products